Condition of surface table

Before specifying a paint system, you will need to find out what condition the existing surface is in. This table helps with this classification.

Code Name Description
A New New surface requiring cleaning and minimal preparation to receive surface coating application.
B Uncoated Existing uncoated surface having had some degree of exposure to natural conditions but requiring minimal preparation.
C Factory Coated/Primed New or existing surface with factory applied coating or factory applied primer, requiring some cleaning and preparation.
D No Breakdown Coated surface in excellent condition showing no coating failure, minimal cleaning and preparation required.
E Light Failure
(< 20%)
Coatings showing some breakdown (< 20%) not only in high wear areas, surfaces will require wash-down, scraping back of failed coatings and some minor surface repairs.
F Partial Removal (20-50% Failure) Medium breakdown of existing coatings (20-50%), failed coatings and high wear areas should be stripped and repairs undertaken.
G Heavy Failure/ Incompatible Coatings All coatings should be completely removed prior to repairs taking place.
H Wall Coverings (good) Minor breakdown of existing wall coverings. Surfaces should be cleaned down and minor repairs undertaken, existing paper should be stuck down.
J Wall Coverings (poor) Major breakdown of existing wall coverings. Completely remove existing coverings using a suitable method, repair surfaces as necessary.
K New Hot Rolled Steel Grade A, B, C, D as described in BS 7079 Part A1 1989
L Cold Rolled Steel New or Weathered
M Cast/Wrought Iron New or Weathered
N Hot Dipped Galvanised & Zinc Metal New or Weathered
P Metal Sprayed New
Q Cast Aluminium New or Weathered
R Polished Extruded Aluminium New or Weathered
S Copper Lead & Brass New
T Plastisol Coated Coil Cladding Weathered with No Breakdown
Defective Coatings (partial strip)
Complete Strip of Defective Coatings
U Metal Gutters (interiors) Metal Gutters (interiors)
X1 Problem Surfaces Difficult Surfaces Non Decorative Coated
X2 Problem Surfaces Road Marking Surfaces Coated and Uncoated
RE1-3 Previously factory primed or fully coated metal (0.05%-1.00% failure) As per European Scale of Rusting
Systems for Factory Primed Steel Systems for Steel with a full system previously applied
RE4-5 Previously factory primed or fully coated metal (3%-8% failure) As per European Scale of Rusting
Systems for Factory Primed Steel Systems for Steel with a full system previously applied
RE6-10 Previously factory primed or fully coated metal (15%-100% Failure) As per European Scale of Rusting